100% Guaranteed Results


ECE 8813A
$ 20.99
Category:

Description

5/5 – (1 vote)

Problem Set #4

Watch the following videos:
(a) https://youtu.be/C-BXzVBoJ3U : Algorithmic State Machine
(b) https://youtu.be/5EcYI0NfvXg : Watching from time 0 to 21 minutes is required. The rest of the video is optional.

PROBLEM 4.1:
Given: Farmer John has given some additional design clarifications. There are 10 zones that he wants to control. Each zone has different requirements for water, so he wants to be able to configure the times for each zone. The water pump is only large enough to water one zone at a time and so it is very important to only water 1 zone at a time regardless of the timing that is programmed. If more than one zone is set to be watered at time you must set the output to only water one zone and set the error out value to 1.
module hw4 sprinkler ( clk , rain sensor in , gps data in , gps valid in , programvalid in , program zone in , program time in , zoneactive out , error out )
//Inputs
input clk ;
input rain sensor in ;
input [7 :0 ] gps data in ; input gps valid in ; input program valid in ; input [4 :0 ] program zone in ; input [31:0] program time in ;
//outputs output [9 :0 ] zone active out ; output error out ;
Where program zone in is set according to Table 1. The value of program zone in is passed as an unsigned value from 1 to 20. The value of program time in is set in the format hhmm in ASCII format. The program valid in must be held high for 1 clock cycle to indicate the data on the program zone in and program time in are valid.
Table 1: Programming Zone Description
Value Description Value Description
1 Zone 1 Start Time 2 Zone 1 End Time
3 Zone 2 Start Time 4 Zone 2 End Time
5 Zone 3 Start Time 6 Zone 3 End Time
7 Zone 4 Start Time 8 Zone 4 End Time
9 Zone 5 Start Time 10 Zone 5 End Time
11 Zone 6 Start Time 12 Zone 6 End Time
13 Zone 7 Start Time 14 Zone 7 End Time
15 Zone 8 Start Time 16 Zone 8 End Time
17 Zone 9 Start Time 18 Zone 9 End Time
19 Zone 10 Start Time 20 Zone 10 End Time
A file (zone program.txt)has also been attached to this assignment. Farmer John provided this file as an example watering schedule. The first column of the file is the program zone in and the second column is the program time in that should be passed to the module in ASCII format.